Operating and installation manual for VR 61 mixer module18
Display
screen
Title display
screen
adjustable
operating values
(just display = A)
Remarks Unit Min.
value
Max.
value
Step width Preset
value
C21 Total system
parameters
Mode Auto_OFF Determines the heating
control outside the
programmed time
window
Frost
protection,
ECO, set-back
Frost
protection
Frost protection
delay time
Delay time of the start of
the frost protection
function or the ECO
function.
Hrs. 0 12 1 4
Max. pump blocking
time
If the feed set target
temperature is achieved
for a longer period of
time, the heating is
switched off for the
prescribed pump
blocking time (dependent
upon the external
temperature)
Mins. Off, 5 60 1 15
C22 Total system
parameters
Max. pre-heating
time
Before the start of the
first time window
Mins. 0 300 10 0
Max. pre-switch off
time
Before the end of a time
window
Mins. 0 120 10 0
AT through-heating External temperature
from which continuous
through-heating takes
place
°C OFF,
-25
+10 1 Off
Excess temperature Increases the set heating
circuit target value this
can, in certain
circumstances, improve
the control performance
of the mixer;
if, in A2, for heating
circuit mode HC2 "Zone"
is selected (hydraulic
drawing 4) the value 0
for excess temperature is
applicable
R0151 0
C23 Floor drying
HC2 does not
appear if
"Zone" selected
in heating
circuit mode
HC2 in A2
(Hydraulic
drawing 4)
floor drying - day See Section 7.3Function
floor drying
Day 0 29 1 0
floor drying/feed
target value (A)
See Section 7.3Function
floor drying
°C in accordance
with
temperature
profile
C24 Service Telephone number
FHW
Entry of the telephone
number for the service
requirement
Changing the code
number
0000 9999 each 1 1000
Maintenance date Day/Month/Year
adjustable
C25 Tools Outside
temperature
correction
Matching of the external
sensor
R-551,0 0
Correction room
actual value
Matching the room
temperature sensor
R-330,5 0
Display contrast 0 15 1 6
C26 Software
versions
Software-Version
VR 61 (A)
Display of version
number
Table 7.2 Display screens in the level for the expert technician
(continuation)
7 Start-up
For latest prices and delivery to your door visit MyTub Ltd - 0845 303 8383 - www.mytub.co.uk -