15Operating and installation manual for VR 61 mixer module
Display
screen
Title display
screen
adjustable
operating values
(just display = A)
Remarks Unit Min.
value
Max.
value
Step width Preset
value
C1 HC1
Information
Feed set target (A) Flow temperature target
value
°C 1
Pump status (A) On, Off
FBG connection /
room actual value
Remote control
connected?
Room actual display
°C Yes, no and
0.5
C2 HC2
Information
Feed set target (A) Flow temperature target
value
°C 1
Actual feed VF2 (A) Actual temperature feed
sensor 2;
does not appear if
"Zone" selected in
heating circuit mode HC2
in A2
(Hydraulic drawing 4)
°C 1
Mixer status (A) does not appear if
"Zone" selected in
heating circuit mode HC2
in A2
(Hydraulic drawing 4)
Open, closed,
off
Pump status (A) On, Off
FBG connection /
room actual value
Remote control
connected?
Room actual display
°C Yes, no and
0.5
C3 Hot water
generator
information
Installation sensor
VF1 (A)
Actual value at the feed
sensor 1 or the internal
sensor of the heat
generator
°C 1
Status
flame heating unit
(A)
Off, heating
mode, hot
water mode
C4 Hot water
information
Values appear
only if "active"
is selected for
storage tank in
A2
Current hot water
set target value (A)
Hot water set target
temperature of the
storage tank
°C 1
Storage probe 1 (A) Hot water actual
temperature of the
storage tank
°C 1
Charging pump
status (A)
appears only if in A3 for
relay output"LP"has
been selected
On, Off
Circulation pump
status (A)
On, Off
C8 HC1
parameters
Heating circuit type
(A)
Status display Heating
circuit,
inactive
Switch-on room
temperature
selectable with wall
mounting of the
controller or remote
control
none,
intervention,
thermostat
none
Summer operation
mode Offset
If the outside
temperature > target
room temperature +
Summer Offset, the
heating unit switches off
R0301 1
Table 7.2 Display screens in the level for the expert technician