Proceed as follows to fill the heating system:
> Open all radiator valves (thermostatic radiator valves) of
the heating system.
> Connect the filling cock for the heating system, as
explained by your approved competent person, to a cold
water draw-off valve.
> Open the filling cock slowly.
> Fill it with water using the draw-off valve until the
required filling pressure is reached in the display.
> Close the draw-off valve.
> Bleed all the radiators.
> Then check the filling pressure on the display.
> Fill with more water if required.
> Close the filling cock.
> Remove the connection between the filling cock and the
draw-off valve.
> Return to the basic display.
5.2 Setting the heating flow temperature
5.2.1 Setting the heating flow temperature
without a controller connected
60
Target flow temp.
Back
5.5 Setting the heating flow temperature
If no external controller is connected to the boiler, set the
heating flow temperature according to the respective out-
side temperature as follows:
> Press the right-hand selection button
("
").
The value of the heating flow temperature appears in the
display.
> Use the minus button
or the plus button
to change the heating flow temperature.
> Confirm the change by pressing the right-hand selection
button
("OK").
The heating flow temperature is factory-set for tempera-
tures up to 75°C.
If higher (or lower) values can be set on your boiler, this
means that your approved competent person has calibrated
your unit to adjust the maximum temperature to your heat-
ing system.
5.2.2 Using a controller to set the heating flow
temperature
If your boiler has a weather compensator or a room ther-
mostat control system, you must make the following set-
tings:
> Set the maximum heating flow temperature on the boiler
(¬Section 5.2.1).
The actual heating flow temperature is automatically
adjusted by the controller (for information about this, see
the controller operating instructions).
5.3 Hot water production with VUW boilers
a
Danger!
Risk of being scalded by hot water.
There is a danger of scalding at the hot
water draw-off points if the hot water tem-
peratures are greater than 60°C. Young
children and the elderly can even be at dan-
ger at lower temperatures.
> Select the temperature so that nobody is
at risk.
a
Danger!
Possible danger to life from legionella!
If the boiler is used to reheat water in a
solar-based drinking water heating system,
note the following:
> Set the minimum hot water temperature
to 60°C.
b
Caution!
Risk of damage caused by calcification.
If the water hardness is greater than
3.57 mol/m
3
(= 357 mg/l CaCO
3
), there is a
risk of calcification.
> Set the water temperature to a maximum
of 50°C.